Supplier Homepage Electronic Electronic circuit cooling components heat sink Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor

Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor

Purchase Qty. / Reference FOB Price
Production Capacity:
Payment Terms: LC, T/T, D/P

Basic Info

Model NO.
3x50+54.6
Material Shape
Round Wire
Range of Application
Primarily Overhead Secondary Distribution
Certification
ISO9001, CCC
Brand
Jytop
Standard
ASTM
Ambient Temperature
25 ºC
Ampacity Rating
75ºC
Emissivity
0.91
Coefficient of Absorbtion
0.95
Apply for
Aerial Buindled Cable Overhead Transmission Line
Trademark
JYTOP
Transport Package
500m / Rolls
Specification
ASTM standards
Origin
Zhengzhou, China
HS Code
8544492100
Quadruplex Service Drop ABC Aerial bundled Cable 3x25+54.6 Aluminium conductor

Construction:

Conductors are concentrically stranded, compressed 1350-H19 aluminum, Insulated with either polyethylene or XLP cross-linked polyethylene, Neutral messengers are concentrically stranded 6201, AAC or ACSR .
 
Applications:
Quadruplex Service Drop is used to supply 3 phase power, usually from a pole mounted transformer to the user"s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
 
Standards:
Quadruplex service drop cable meets or exceeds the following ASTM specifications:
ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-399 Concentric-Lay-Stranded Aluminum Alloy Conductors 6201-T81.
 
Service drop cable meets or exceeds all applicable requirement of ANSI/ ICEA-S-76-474:

 

Technical characteristics :

CoresNominal cross-sectional areaPhase Conductors
insulation
Dia. Of cableR. of conductors at 20ºCBreak strength of conductor
Ω/kmKN
3C+1Cmm2Thickness (mm)mmPhase coresNeutral coresPhase coresNeutral cores
3C+1C3x25+54.61.423.571.20.63016.616.6
3C+1C3x35+54.61.626.080.8680.63016.616.6
3C+1C3x50+54.61.628.150.6410.63016.616.6
3C+1C3x70+54.61.832.150.4430.63016.616.6
3C+1C3x70+54.61.832.150.4430.63016.616.6
3C+1C3x70+701.832.750.4430.50020.520.5
3C+1C3x95+701.835.780.320.50020.520.5
3C+1C3x120+701.837.930.2530.50020.520.5
3C+1C3x120+701.837.930.2530.50020.520.5
3C+1C3x120+951.839.260.2530.34327.527.5
3C+1C3x150+951.941.810.2060.34327.527.5

More about ABC Cable types, Plz contact our team. we"ll give reply ASAP.


1. Duplex Service Drop cable : 

Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacityStandard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAluminumTotal
mmmmmmkgAmm
             
AAC
Pekingese6-Solid1.144.16.46-725520.872.994783051000
Collie6-71.144.66.96-725523.872.997783051000
Cocker6-71.524.67.76-725532.772.9106783051000
Dachshund4-Solid1.145.27.56-740026.8114.6141103305500
Spaniel4-71.145.98.26-740029.8116.1146103305500
Cairn4-71.525.98.96-740040.2116.1156103305500
Doberman2-71.147.49.72-7612 38.7184.5223136152500
Airedale1-191.528.411.51-7---56.5233.6290158152500
Basset1/0-71.529.312.41/0-7903 64.0 294.7359182152457
Malemure1/0-191.529.412.51/0-7903 64.0 294.7359182152457
             
AAAC
Chihuahua6-Solid1.144.16.46-749920.872.994783051000
Vizsla6-71.144.66.96-749923.872.997783051000
Harrier4-Solid1.145.27.54-779826.8116.1143103305500
Whippet4-71.145.98.24-779829.8116.1146103305500
Schnauzer2-71.147.49.72-71,270 38.7184.5223136152500
Afghan1/0-71.529.312.41/0-72,023 64.0 296.1360182152457
heeler1/0-191.529.412.51/0-72,023 64.0 296.1360182152457
             
ACSR
Setter6-Solid1.144.16.46/6/0154020.872.994783051000
Shepherd6-71.144.66.96/6/0154023.872.997783051000
Retriever6-71.524.67.76/6/0154032.772.9106783051000
Eskimo4-Solid1.145.27.54/6/0184426.8114.6141103305500
Terrier4-71.145.98.24/6/0184429.8116.1146103305500
Yorkshire4-71.525.98.94/6/0184440.2116.1156103305500
Chow2-71.147.49.72/6/011,293 38.7184.5223136152500
Labrador1-191.528.411.51/6/011,610 56.5233.6290158152500
Bloodhound1/0-71.529.312.41/0-6/11,987 64.0 294.7359182152457
Bull1/0-191.529.412.51/0-6/11,987 64.0 294.7359182152457

2. Triplex Service Drop cable :

Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacityStandard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAlTotal
mmmmmmkgAmm
             
AAC
Halotis6-Solid1.144.1156.46-725542 11015278305762
Pike6-70.764.676.26-725531 11214378305762
Patella6-71.144.677.0 6-725548 11215978305762
Albus6-71.524.677.76-725564 13219878305762
Fusus4-Solid1.145.1827.54-740052 177229103152518
Oyster4-71.145.898.24-740060 177237103152457
Argo4-71.525.898.94-7400 80 177258103152457
Clam2-71.147.429.72-7612 76 281359136152549
Thia2-71.527.4210.52-7612 100 281383136152549
Mussel2-71.147.429.72-7612 76 281359136152549
Pyrula1-71.528.3311.41-7744113 356467158152457
Hyas1-191.528.4311.51-7744115 356469158152457
Murex1/0-71.529.3512.41/0-7903128 385513182152366
Purpura1/0-191.529.4712.51/0-7903130 385515182152366
Nasa2/0-71.5210.5213.62/0-71,139 146 566710210-457
Trophon2/0-191.5210.6413.72/0-71,139 147 566713210-457
Quahog3/0-72.0311.7915.93/0-71,379 214 713926242-396
lone3/0-192.0311.9416.0 3/0-71,379 217 713929242-396
Melita3/0-191.5211.9415.0 3/0-191,501 168 713881242-396
Coquila4/0-71.5213.2616.34/0-71,737 191 8991,089 279-305
Tusk4/0-72.0313.2617.34/0-71,737 243 8991,141 279-305
Apus4/0-192.0313.4117.54/0-71,737 246 8991,144 279-305
Portunus4/0-191.5213.4116.54/0-191,823 194 8991,091 279-305
Chiton266.8-192.0314.8818.9266.8-192,254 277 1,133 1,409 310-305
Nannynose336.4-192.0316.9221.0 336.4-192,790 321 1,427 1,749 330-305
 


Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacityStandard
 Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAluminumTotal
mmmmmmkgAmm
AAAC
Homarus6-Solid1.144.1156.46-749942 11815978305762
Minex6-Solid1.144.11513.36-749942 11815978305762
Cabera6-71.144.656.9 6-749948 11816578305671
Hippa6-71.144.656.96-749948 11816578305671
Artemia4-Solid1.145.1827.56-749952 162214103305518
Maira4-71.145.898.26-749960 188247103305518
Crab4-71.145.898.26-749960 162222103305518
Luidia4-Solid1.145.1827.56-749952 162214103152518
Prawn4-Solid1.145.1827.54-7798 52 188240103152518
Metalia4-71.145.898.24-7798 60 188247103152457
Barnacles4-71.145.898.24-7798 60 188247103152457
Solaster2-71.147.429.74-7798 76 258333136152549
Pagarus2-71.527.4210.54-7798 100 258357136152549
Shrimp2-71.147.429.72-71,270 76 298374136152549
Lobster2-71.527.4210.52-71,270 100 298397136152549
Encope1-191.528.4311.52-71,270 115 347461158152366
Sanderab1/0-71.529.3512.42-71,270 128 409537182152366
Echinus1/0-191.529.4712.5 2-71,270 130 409539182152366
Gammarus1/0-71.529.3512.41/0-72,023 128 473601182152366
Leda1/0-191.529.4712.51/0-72,023 130 473603182152366
Crayfish2/0-71.5210.513.6 2-71,270 146 487631210-457
Sipho2/0-191.5210.613.72-71,270 147 487634210-457
Dungenese2/0-71.5210.513.6 2/0-72,445 146 595740210-457
Cyclops2/0-71.5210.613.72/0-72,445 147 595743210-457
Slug3/0-71.5211.814.81/0-72,023 165 650816242-366
Fulgur3/0-191.5211.915.0 1/0-72,023 168 650819242-366
Balanus3/0-192.0311.916.0 1/0-72,023 216 650868242-366
Stonecrab3/0-71.5211.814.8 3/0-73,080 165 752917242-366
Flustra3/0-71.5211.915.0 3/0-73,080 168 752920242-366
Crisia3/0-192.0311.916.0 3/0-73,080 216 752969242-305
Squid4/0-71.5213.316.32/0-72,431 191 8201,011 279-305
Arca4/0-191.5213.416.52/0-72,431 192 8201,012 279-305
Bugula4/0-192.0313.417.52/0-72,431 246 8201,066 279-305
Kingerab4/0-71.5213.316.34/0-73,883 191 9481,137 279-305
Lepas4/0-191.5213.416.54/0-73,883 192 9481,140 279-305
Cassi4/0-192.0313.417.5 4/0-73,883 246 9481,194 279-305
 


Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacityStandard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAlTotal
mmmmmmkgAmm
ACSR
Paludina6-Solid1.144.1156.401 6-6/154042 11217079305762
Voluta6-71.144.676.960 6-6/154048 11217679305671
Bolma6-71.524.677.722 6-6/154064 11219479305671
Scallop4-Solid1.145.1827.468 6-6/154052 155225138152518
Strombus4-71.145.898.179 6-6/154060 155232138152457
Carnea4-71.525.898.941 6-6/154080 155253138152457
Whelk4-Solid1.145.1827.468 4-6/184452 177258138152518
Periwinkle4-71.145.898.179 4-6/184460 177263138152457
Calma4-71.525.898.941 4-6/184480 177284138152457
Cockle2-71.145.898.179 4-6/184460 247335183152549
Gebia2-71.525.898.941 4-6/1844 80 247354183152549
Conch2-71.145.898.179 2-6/11,293 60 281384183152549
Uca2-71.525.898.941 2-6/11,293 80 281405183152549
Vermeths1-71.528.3311.379 1-6/11,610 113 354522210152457
Atya1-191.528.3311.379 1-6/11,610 113 430524210152457
Janthina1/0-71.528.3311.379 2-6/11,293 113 393549242152366
Ranella1/0-191.529.4712.522 2-6/11,293 130 393566242152366
Neritina1/0-71.529.3512.395 1/0-6/11,987 128 448644242152366
Cenia1/0-191.529.4712.522 1/0-6/11,987 130 448646242152366
Cavolinia2/0-71.5210.513.564 1-6/11,610 146 496697279-579
Clio2/0-191.5210.613.691 1-6/11,610 147 496698279-457
Runcina2/0-71.5210.513.564 2/0-6/12,404 146 564796279-457
Triton2/0-191.5210.613.691 2/0-6/12,404 147 564799279-457
Sanddollar3/0-71.5211.814.834 1/0-6/11,987 165 625860322-396
Aega3/0-191.5211.914.986 1/0-6/11,987 168 625862322-396
Pisa3/0-192.0311.916.002 1/0-6/11,987 216 625911322-396
Cherrystone3/0-71.5211.814.834 3/0-6/13,003 165 711987322-396
Mursia3/0-191.5211.914.986 3/0-6/13,003 168 711990322-396
Mysis3/0-192.0311.916.002 3/0-6/13,003 216 711990322-396
Cuttlefish4/0-71.5213.316.307 2/0-6/12,404 191 7871,066 372-305
Cerapus4/0-191.5213.416.459 2/0-6/12,404 192 7871,069 372-305
Nepatus4/0-192.0313.417.475 2/0-6/12,404 246 7871,121 372-305
Razor4/0-71.5213.316.307 4/0-6/13,788 191 8971,226 372-305
Zuzara4/0-191.5213.416.459 4/0-6/13,788 192 8971,229 372-305
Alima4/0-192.0313.417.475 4/0-6/13,788 246 8971,281 372-305
Callista266.8-192.0315.119.126 3/0-6/13,003 280 9941,384 410-305
Dosinia266.8-192.0315.119.126 266.8-18/13,121 280 1,133 1,472 410-305
Cowry336.4-192.0316.920.980 4/0-6/13,788 320 1,253 1,713 506-305
Limpet336.4-192.0316.920.980 336.4-18/13,937 320 1,429 1,823 506-305

3.Quadruplex Service Drop Cable :

Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacity*Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAluminumTotal
mmmmmmkgAmm
             
AAC
Quarter6-Solid1.1434.1156.4016-7255.3716314921178152.4762.0
Clydesdale4-Soild1.1435.1827.4684-7399.61379237315103152.4518.2
Pinto4-71.1435.8938.1794-7399.61389237326136152.4518.2
Musang2-71.1437.4179.7032-7612.347115377491158 548.6
Shire1-191.5248.43311.4811-19743.888171475646158 457.2
Libyan1/0-71.5249.34712.3951/0-7902.644192598790182 365.8
Criollo1/0-191.5249.47412.5221/0-19902.644193598793182 365.8
Orloff2/0-71.52410.51613.5642/0-71138.511217754973210 457.2
Percheron2/0-191.52410.64313.6912/0-191138.511220754976210 457.2
Mongolian3/0-71.52411.78614.8343/0-71378.9142499511199242 396.2
Hanoverian3/0-191.52411.93814.9863/0-191378.9142519511204242 396.2
Singlefoot4/0-71.52413.25916.3074/0-71737.25028611991485279 335.3
Oldenburg4/0-191.52413.41116.4594/0-191737.25028911991490279 335.3
 


Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacity*Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAluminumTotal
mmmmmmkgAmm
             
AAAC
Bay6-Solid1.1434.1156.4016-7503.4856315521778152.4762.0
French-conch6-71.1434.6746.9606-7503.4857115522678152.4762.0
German-conch4-solid1.1435.1827.4684-7798.31879247324103152.4518.2
Arabian4-71.1435.8938.1794-7784.71189247336103 518.2
Belgian2-71.1437.4179.7032-71270.052115391506136 548.6
Saddle1-191.5248.43311.4812-71270.052171466637158 457.2
Plow1/0-71.5249.34712.3951/0-72023.011192624814182 365.8
Sherland1/0-191.5249.47412.5221/0-72023.011193624817182 365.8
Dapple-grey2/0-71.52410.51613.5642/0-72444.8502177861005210 457.2
Thoroughbred2/0-191.52410.64313.6912/0-72444.8502207861007210 457.2
Dobbin3/0-71.52411.78614.8343/0-73079.8762499911238242 396.2
Troter3/0-191.52411.93814.9863/0-73079.8762519911243242 396.2
Pony4/0-71.52413.25916.3074/0-73882.73028612501534279 335.3
Walking4/0-191.52413.41116.4594/0-73882.73028912501539279 335.3
 


Code
Word
Phase ConductorsBare NaturalNominal WeightAmpacity*Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal DiameterSize &
Number
of Wires
Rated
Strength
kg / kmCoilsReels
BareODXLPEAluminumTotal
mmmmmmkgAmm
             
ACSR
Morochuca6-Solid1.1434.1156.4016-6/1539.7726314922978152.4762.0
Chola6-71.1434.6746.9606-6/1539.7727114923778152.4762.0
Morgan4-solid1.1435.1827.4684-6/1843.66779238344103152.4518.2
Hackney4-71.1435.8938.1794-6/1843.66789238356103 518.2
Palomino2-71.1437.4179.7032-6/11292.732115377557136 548.6
Albina1-191.5248.43311.4812-6/11610.245171473699158 457.2
Standardbred1/0-71.5249.34712.3951/0-6/11986.724192598859182 365.8
Costena1/0-191.5249.47412.5221/0-6/11986.724193598862182 365.8
Chicoeagues2/0-71.52410.51613.5642/0-6/12404.0272177531060210 457.2
Grullo2/0-191.52410.64313.6912/0-6/12402.0272207531063210 457.2
Mare3/0-71.52411.78614.8343/0-6/13002.7662499511308242 396.2
Suffolk3/0-191.52411.93814.9863/0-6/13002.7662519511313242 396.2
Stallion4/0-71.52413.25916.3074/0-6/13787.47728611981622279 335.3
Appaloosa4/0-191.52413.41116.4594/0-6/13787.47728911981627279 335.3

* Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201. Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft/sec. wind in sun.
** To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.
The data is approximate and subject to normal manufacturing tolerances.



 

Send Inquiry to this supplier

People who viewed this also viewed

FOB Price: US $1 / Meter
Min. Order: 5000 Meters
FOB Price: US $1 / Meter
Min. Order: 5000 Meters
FOB Price: US $1 / Meter
Min. Order: 5000 Meters
FOB Price: US $0.5 / Meter
Min. Order: 5000 Meters

You Might Also Like

FOB Price: US $4569/piece
FOB Price: US $4568/piece
FOB Price: US $0.6 / Piece
Min. Order: 100 Pieces
FOB Price: US $2.68 / Meter
Min. Order: 500 Meters
FOB Price: $20 - $60 / Box
Min. Order: 100 Boxes
FOB Price: $20 - $60 / Box
Min. Order: 100 Boxes
FOB Price: $0.5 - $0.8 / Piece
Min. Order: 10 Pieces

Send Inquiry to this supplier

Contact Us | User Agreement | Privacy Policy | 加入会员

Service Tel: (+86)0571-87774297